RAD-Galaxy
Multi Active Tap & Gateway for Automotive EthernetGeneral Specifications
- Fourth-generation neoVI architecture: over 10x the performance of earlier devices
- Low power consumption
- Power Supply: 4.5-40V operation
- 20 LEDs indicate link status and logger status
- Temperature Range: -40°C to +85°C
- One-year limited warranty
- Field-upgradeable flash firmware
- Four MISC I/O channels configurable as 0-40V analog input or PWM input or output
- Three 0-5V analog outputs
- Standalone mode including scripting, receive messages, transmit messages, expressions, I/O, and transport layers
- J2534 and RP1210 A/B compatible for CAN/ISO15765
- Full-size SD card slot with support for cards with capacities up to 128 GB (or the limit of newer SDHC cards); card is formatted using FAT32 for PC compatibility.
- Battery-backed real time clock (RTC).
- Dimensions: 10.63” x 4.53” x 1.57” (27cm x 11.5cm x 4cm)
- Weight: 1.42 lbs (645g)
Timing Specifications
- FPGA-measured 64-bit timestamping with 10 ns accuracy on all CAN/LIN/Ethernet networks
- Simultaneous operation on all CAN/LIN/Ethernet networks
- Transmit message double-buffering on all networks, allowing back-to-back message transmission
Network Specifications – Automotive Ethernet
- 12 Broadcom BroadR-Reach® (100BASE-T1) Automotive Ethernet physical layer transceivers
- PHYs can be configured to operate as active taps for up to 6 node pairs, media converters for up to 12 nodes, or a combination of up to 6
- Full-duplex operation on all links
- Automatic master/slave configuration
Network Specifications – CAN
- 6 Dedicated ISO11898 Dual Wire CAN channels with ISO CAN FD support
- 2 additional CAN channels switchable between ISO CAN FD or SW CAN (GMW3089 / SAE J2411)
- Up to 1 Mb/s software-selectable arbitration phase baud rate
- Up to 8 Mb/s software-selectable data phase baud rate for CAN FD
- Listen-only mode support
- Single Wire High Speed Mode, Test Tool Resistor, and High Voltage Wakeup support
- CAN FD implemented using the Bosch MCAN CAN Controller IP
Network Specifications – LIN
- 1x LIN (Local Interconnect Network)
- Full support for LIN 1.X, 2.X and J2602
- LIN J2602 / 2.X compatible physical layer
- Software-enabled 1K LIN Master Resistor per channel
- LIN Bus Monitor Mode identifies errors: Sync Break Error State and Length, Sync Wave Error, Message ID parity, TFrameMax/Slave Not Responding, Checksum Error and Transmit Bit Errors
- LIN Bus Master Mode operates at same time as LIN Bus Monitor
- LIN Bus Slave simulation, with or without an LDF file
- LIN Bus hardware schedule table with support for LIN diagnostics
- Software-selectable baud rate
Network Specifications – DoIP/XCP/Automotive Ethernet
- 10/100/1000 Ethernet PHY with low-power mode
- DoIP activation line implemented with LIN channel
* Specifications subject to change. Please contact Intrepid for the latest information.