1-800-859-6265   FAX: +1 (586) 731-2274

RAD-Galaxy

Multi Active Tap & Gateway for Automotive Ethernet
General Specifications

  • Fourth-generation neoVI architecture: over 10x the performance of earlier devices
  • Low power consumption
  • Power Supply: 4.5-40V operation
  • 20 LEDs indicate link status and logger status
  • Temperature Range: -40°C to +85°C
  • One-year limited warranty
  • Field-upgradeable flash firmware
  • Four MISC I/O channels configurable as 0-40V analog input or PWM input or output
  • Three 0-5V analog outputs
  • Standalone mode including scripting, receive messages, transmit messages, expressions, I/O, and transport layers
  • J2534 and RP1210 A/B compatible for CAN/ISO15765
  • Full-size SD card slot with support for cards with capacities up to 128 GB (or the limit of newer SDHC cards); card is formatted using FAT32 for PC compatibility.
  • Battery-backed real time clock (RTC).
  • Dimensions: 10.63” x 4.53” x 1.57” (27cm x 11.5cm x 4cm)
  • Weight: 1.42 lbs (645g)

Timing Specifications

  • FPGA-measured 64-bit timestamping with 10 ns accuracy on all CAN/LIN/Ethernet networks
  • Simultaneous operation on all CAN/LIN/Ethernet networks
  • Transmit message double-buffering on all networks, allowing back-to-back message transmission

Network Specifications – Automotive Ethernet

  • 12 Broadcom BroadR-Reach® (100BASE-T1) Automotive Ethernet physical layer transceivers
  • PHYs can be configured to operate as active taps for up to 6 node pairs, media converters for up to 12 nodes, or a combination of up to 6
  • Full-duplex operation on all links
  • Automatic master/slave configuration

Network Specifications – CAN

  • 6 Dedicated ISO11898 Dual Wire CAN channels with ISO CAN FD support
  • 2 additional CAN channels switchable between ISO CAN FD or SW CAN (GMW3089 / SAE J2411)
  • Up to 1 Mb/s software-selectable arbitration phase baud rate
  • Up to 8 Mb/s software-selectable data phase baud rate for CAN FD
  • Listen-only mode support
  • Single Wire High Speed Mode, Test Tool Resistor, and High Voltage Wakeup support
  • CAN FD implemented using the Bosch MCAN CAN Controller IP

Network Specifications – LIN

  • 1x LIN (Local Interconnect Network)
  • Full support for LIN 1.X, 2.X and J2602
  • LIN J2602 / 2.X compatible physical layer
  • Software-enabled 1K LIN Master Resistor per channel
  • LIN Bus Monitor Mode identifies errors: Sync Break Error State and Length, Sync Wave Error, Message ID parity, TFrameMax/Slave Not Responding, Checksum Error and Transmit Bit Errors
  • LIN Bus Master Mode operates at same time as LIN Bus Monitor
  • LIN Bus Slave simulation, with or without an LDF file
  • LIN Bus hardware schedule table with support for LIN diagnostics
  • Software-selectable baud rate

Network Specifications – DoIP/XCP/Automotive Ethernet

  • 10/100/1000 Ethernet PHY with low-power mode
  • DoIP activation line implemented with LIN channel

* Specifications subject to change. Please contact Intrepid for the latest information.