Pinout

Pin Signal
1 T1S IN #1 (10BASE-T1S positive – Tap A)
2 T1S OUT #1 (10BASE-T1S negative – Tap A)
3 T1L P (10BASE-T1L positive)
4 RS485 P (Modbus positive)
5
6 CAN H (CAN/CANFD high)
7
8 GND (Ground)
9 T1S IN #2 (10BASE-T1S positive – Tap B)
10 T1S OUT #2 (10BASE-T1S negative – Tap B)
11 T1L N (10BASE-T1L negative)
12 RS485 N (Modbus negative)
13 MISC DIO (General purpose I/O) – 5V
14 CAN L (CAN/CANFD low)
15 VBATT

 